Model Number : DS1500
P/N : | DS15-G000-00-3 |
---|---|
Rated Power : | 1.5 kw |
Rated Wind Speed | 12 m/s |
Rated Speed : | 250 rpm |
Cut-In Wind Speed : | <3 m |
Cut-Out Wind Speed : | 15 m/s |
Survival Wind Speed : | 60 m/s |
Rotor Diameter : | 2.8 m |
---|---|
Rotor Height : | 2.99 m |
Mast Height(Not Included) : | 4 m |
Total Height : | 6.99 m |
Total Weight : | 380 KGS (Mast not included) |
External Darrieus | 3 Blades |
---|---|
Internal Savonius : | 2 Layers |
Material of Blades : | Anodized Aluminum |
Material of Axis : | Galvanized Steel SS400 |
Generator Type : | AC, 3 Phase, Synchronism PMG |
---|---|
Rated Output : | 1.5 k w |
Automatic Braking : | Automatic Dump-load and 3-phase short circuit braking system |
---|---|
Manual Braking : | Mechanical Drum Brake |
Ambient Temperature : | -10~40°C |
---|---|
Ambient Humidity : | 95% max. |
Model : | WT21500 |
---|---|
Part Number : | |
Output Power : | 1500 w |
Max. Power : | 1600 w |
Nominal AC Voltage : | 200Vac rms |
Working Range : | 48Vac±5%~230Vac±5% |
MPPT Range : | 48~210Vac |
Initial Feeding Voltage : | 48Vac |
Max. Input Current : | 15A |
System Cut-out Voltage : | 240V |
Operational Voltage : | 192~254VAC |
Max. Output Current : | 9A |
Operational Frequency : | 50/60Hz |
Power Factor : | >0.99 @ Full-load |
Current Distortion : | <5% |
Max. Efficiency : | >90% |
Anti-islanding : | Yes |
Protection Degree : | IP45 |
Operation Temperature : | -20~40°C |
Humidity : | 0~95% Non-Condensing |
Heat Dissipation : | Convection |
Acoustic Noise Level : | <40dB, A-weighted |
Communication and Features : | RS232 Standard, SNMP Optional (SNMP not available yet) |
Dimension(in mm) : | 480W x 370L x 185L |
Weight : | 20 Kgs |
Certificate : | VDE0126/CE |
Nominal Power : | 1.5KVA |
---|---|
Max. DC Power : | PDC, max.: 1600W |
Max. DC voltage : | VDC, max. 450 V DC |
Nominal DC range : | VDC 70 V – 400 V DC |
Efficiency : | ηmax> 94 % |
Europe Efficiency : | ηeuro> 92 % |
Max. input current : | IDc, max. 10 A DC |
Voltage ripple : | VPP < 10% |
Pole confusion protection : | Fuse |
Nominal AC Output Power : | 1400W AC |
Max. AC Output Power : | 1500W AC |
Operating Range Utility Voltage : | 200 – 260 V AC |
Operating range utility frequency : | 49– 50.3 Hz |
Total Harmonic Distortion (THD) : | THDIAC < 5 % |
Power Factor : | > 0.98 |
Utility Monitoring : | VAC; fAC Islanding protection VAC; fAC in accordance with ER G83/1, UL 1741,IEEE929 |
Short Circuit Protection : | Current controlled, Fuse |
External Interfaces : | Screw Terminal Block, Data transmission via electrically isolated RS485 |
Internal consumption during operation : | < 15 W |
Internal Consumption During Stand-By : | < 15W |
Night Time Consumption : | < 15 W |
Operation Surroundings Temperature : | -10°C~+40°C |
Operation Surroundings Humidity : | 0~90% |
Dimensions (HxWxD) : | 483x267x124mm |
Weight : | 13 Kgs |
Waterproof : | IP42 |
Certification : | CE |